The
Skenar 97.4 + has been replaced by a new model which is called the RITMProfessional
The RITMSCENAR Professional has full versatility
in parameter adjustment - used as both a diagnostic research and experimental
treatment device. There is a huge amount of research material on this
instrument!
CE
approved for pain
relief in the United
Kingdom!
The new model year 2004 which replaces the RITM profscenar
97.4+.
What is new?
Design, backlight, very low energy option, line screening, circle screening,
service menu and DIAN (Off, 1, 2, 3, 4) leather wallet.
What is improved?
Bigger display, battery compartment (3 AA batteries), keypath, inner circuits
connections, for left and right hand use.
The basic mode of operation of Scenar devices is to deliver a "dosage" of electrical
stimulation impulses to the body via an in-built and/or remote electrode in direct
contact with the skin surface. These impulses have been tailored to mimic the
electrical discharges of the nervous system, in order to elicit the organism's
response with optimum efficiency and minimum disruption to cell function, depending
upon the unique requirements of the presenting pain disease dynamics (or lack
of the same). The action is aimed at both the "fast" pain blocking A-fibres and
the "slow" pain producing and peptide generating C-fibres.
In other words, the Scenar measures the electrical properties
(impedence) of the skin to correct energetic imbalances.
The Scenar measures response and mimics the signals sent
by the brain to instruct the release of healing bio-chemicals
such as neuropeptides. The basic idea is that the body becomes
overwhelmed with so much "patterns of injury" that corrective
electrical signals may not reach the most important injuries.
A trained scenar researcher may be able to correct these
electrical patterns allowing the body to heal
itself much more easily.
The signal stream, comprising waveform, signal strength
(voltage and current) and frequency, can be varied in a
number of ways, either by preselection by the operator
or automatically by the control circuitry of the device.
The "dosage" can
be delivered automatically or overridden at the discretion of the operator, with
guidance from visual indicators on numeri LED display.
The basic signal component is a bipolar pulse,
consisting of a negative
square-wave followed by a positive saw-tooth, starting and finishing
at zero and lasting for a few microseconds. A number of these pulses may be
packaged into a discrete burst (intensity) which
itself may be repeated at a fixed default frequency. The individual pulses
in these bursts (intensity more than 1) can themselves be spaced out (Z=10/close together,
to 80/wide
apart) to give a concentrated
(deep) or diffuse (shallow) penetration, depending on local body density or
depth of pain location.
Alternatively, a single pulse (intensity=1) may be preselected to a pulse repeat
rate (PRP) over a set frequency range (say F=15-351 Hz). The signal may also
be "modulated":
AM=Off, 1:1, 1:2, 1:3, 1:4, 1:5, BEE (amplitude
modulation),
FM=Off, On, Swing (frequency modulation),
DMPF=Off, Sk1, Sk2, Sk3, Sk4, Var.
These "modulations" can either be applied individually or together.
There is also the possibility of automatically cycling both the repeat rate
(PRP) over a set frequency range (FM -say from 30 to 180 Hz over
8 seconds) and the
waveform damping factor (Dmpf =VAR). These cyclical
modes can again be invoked either individually or together.
The purpose of all these variants is to make available to the operator a comprehensive
arsenal with which to stimulate both acute and chronic conditions and prevent
the body from adapting to the signal before there has been time to generate
sufficient neuropeptides (endophins, etc.) to releave pain and create an enhanced
environment for the organism to bring into play its own healing pharmacy to
move towards homeostasis.
The power output can be set by the operator to be detectable but comfortable
for the patient. It can also be adjusted during application should this be
required. The maximum current output is 70 mA and the peak voltage is 180 V,
derived from three internal AA batteries.
A further level of chaos is introduced by a random variation of the pulse amplitude
from zero to the chosen comfort such that no two pulses are the same. This
discourages adaptation in the organism. A feedback mechanism is provided by
the constant monitoring of skin impedance, which will change with time and "dosage" delivered.
Integration of these values permits calculation and display of rate of change
(of current flow) and coefficient of waveform in relation to the starting point.
Scenar devices adhere to the concept that the maximum dosage required to effect
change is the most appropriate. Ths is furthered by emphasis on increase of
information rather than energy content, thus minimising the triggering of body
retaliation and adaptation mechanisms.
Optional attachments: face, scalp and point.
Don't be fooled by look-a-likes. There are a number of units which look very similar to the unit shown below that are actually manufactured in Russia. These units have different software inside and work differently.
Our units are manufactured in Europe and contain no Russian components (this means higher quality construction, better technology that will last the test of time and function better). |